Usus Gw4 Disconnect Switch est 110kV duplex columnae rotationis horizontalis, mediae-fractionis generis ac veli AC summus voltatio disiunctio switch, ad tria phase AC 50/60Hz systemata virtutis accommodata. Praesertim ad aperiendas et claudendas operationes sub voltage-on-onere condiciones adhibita est et punctum clare conspicuum electricae solitudo pro apparatu sustentationis summus intentione praebet. Sicut professionalis summus voltatio switchgear fabrica e Sinis, Zhejiang Usune Electric Co, Ltd., cum suis provectis instrumentis productionis et ratio qualitatis comprehensivae, solidam cautionem praebet pro producto reliabilitate, eumque praelatum apparatum pro substations ac potentiae transmissionis et distributionis inceptis praebet.

Zhejiang Usus Electric Co, Ltd est officinas professionales integrare R&D, consilium, productionem et venditiones. Eius principalis producta includunt 12kV~245kV sub tectis ac velit summus intentione vacuum circa praevaricatores, SF6 ambitum praevaricatores, onere virgas, variasque virgas disiungens. Est fiduciam professionalem amet pro potestate ipsum inceptis tum domestice et internationaliter.

Usus Gw4 Disconnect SWITCH PB nominatim ad tres-phases AC 50Hz/60Hz systemata virtutis destinatur. Eius primaria munus est connectere vel disconnect summus intentionis ambitus sub agere, condiciones nullas onerare et visibiles praebere electrica solitudo alvi ad conservationem busbarum, circa fractores, transformatores, aliaque alta intentione armorum.

1. signa Implemented

-GB 1985-2004: AC High intentione Disconnect SWITCH et Grounding SWITCH
-IEC 62271-102: High intentione Switchgear and Controlgear
-GB/T 11022: Specificationes Generales pro High intentione Switchgear et Controlgear

2. Design Genera

GW4 Series: Duplex insulator, rotationis horizontalis, typus interruptus

Features structuralis

1. Duplex post structuram insulatoris, duo postes insulatores per phase horizontaliter 90° synchrone positi.
2. Principales contactus sunt centrum perrupti, aeris notae argenti patellae, contactus resistentiae humilium et conductivitatis bonae.
3. Basis fit ex ferro galvanizato intinge, signatis gestus, corrosio resistens et durabilis.
4. GW4 Disconnect SWITCH PB instrui potest cum virgas simplices vel duplex postesque institutio, cum mechanica. interlocking ut perficiendis salutem.
5. Mechanismus operans potest esse manualis (CS14G, CS17G) vel electricae (CJ6B, CJ11, XCJ-I).

Pelagus Technical Parametri

Parameter Specification
Ratum Voltage 126kV (110kV ratio)
Rated Frequency 50Hz
Ratum Current 630A, 1250A, 1600A, 2000A, 2500A
Rated breve tempus sustine Current (1s) 31.5kA, 40kA, 50kA
Rated Pecco sustine Current 80kA, 100kA, 125kA
1min arida AC resistendi intentione - Ad terram: 140kV- Per jugum: 160kV
Operatio Temperature -40°C ad +40°C
altitudo ≤ 2000m

Practical application Case

A 110kV... Ventus Power Substation Project

Hoc consilium in regione septentrionali sita est cum differentias temperaturas significantes, magno apparatu requirens commendatio et frigoris resistentia. Exertum multiplex Usune GW4 delectae SW4 Disconnect SWITCH, electrico instructus machinationes et duplex postesque institutio permutat. Multos annos, ex quo mandatum est, apparatum stabiliter operavit; cum certis actionibus mechanicis et resistentia optimae corrosionis, efficaciter ad substationem sustentationem tutandam et quotidiana operationis efficacia, promerendae laudis ex usuin.

Gw4 Disconnect SwitchGw4 Disconnect Switch

Gw4 Disconnect Switch Gw4 Disconnect Switch

Pelagus Technical Parametri

Item Unitas Morbi laoreet
Ratum Voltage kV 40.5 72.5 126 145
Nulla campester rated 1min vim frequency sustinere voltage (valorem efficacem) In terra kV 95 160 230 275
Fractura kV 118 200 230+70 275+85
Rated fulgur impetus current (cacumen) In terra kV 185 350 550 650
Fractura kV 215 410 550+10 650+20
Rated Frequency Hz 50/60
Ratum Current A 630~4000 630~4000 630~4000 630~4000
Rated breve tempus sustinere current KA 20、31.5、40、50 20、31.5、40、50 20、31.5、40、50 20、31.5、40、50
Rated apicem sustinere current KA 50、80、100、125 50、80、100、125 50、80、100、125 50、80、100、125
Ratum spatio brevi spatio Knife/gladius s 4/4 4/4 3/3 3/3
Rated mechanica terminatio onus Horizontalis et verticalis N 1250 1250 1250 1250
Horizontal N 750 750 750 750
Vis verticalis N 1000 1000 1000 1000
Creepage procul mm 1013/1256 1813/2248 3150/3906 3652/4495
Mechanica vita Tempora 5000 5000 1000 5000
Motor actus Exemplar CJ CJ CJ CJ
Motor voltage V AC380、AC220、DC220、DC110
Tentatio imperium loop V AC380、AC220、DC220、DC110
Puncta, occlusio temporis s 7±1

Actus humanus
Exemplar CS14 CS17
Electromagneticum cincinno voltage V AC220、DC220、DC110

Exteriores

Gw4 Disconnect Switch Gw4 Disconnect SwitchGw4 Disconnect SwitchGw4 Disconnect SwitchGw4 Disconnect Switch

INSTALLATION & IMPERIUM

1. metus ante instruitur

• Insulatores: Non rimas, damnum, vel lutum.
• Contactus: mundus, superficies argentea patella integra.
• Fasteners: omnia fulmina constringuntur.
• Mechanismus: rotationis lenis; praelinm mo- tibus.

2. De revolutionibus

• Insulator verticalis: Adjust cum shims (max 3mm per locationem).
• Tres periodi synchronisation: Adjust crank-brachium et virgas nexus.
• Contact pressio: Perficite propriis insertionibus et pressuris.

NEGOTIUM

• Tantum sub NO ONERE agunt; ambitus confirmator, pandens apertus.
• Operatio manualis: Utere manubrio operandi; nimiam vim vitare.
• Operatio motorised: Usus localis/remotus imperium; monitor positio.
• Interlock: Operationem noli opprimere, si interlocked.

VICTUS

• Periodica overhaul: Omnis 1-2 annis.
• Tersus insulatores et contactus; applicare vase industriae.
• Lubricate gestus et partes transmissionis.
• Compesce fulmina laxa, confectus contactos, et damna insulator.
• Post breve spatium: Inspice statim.

TROUBLESHOOTING

• Non potest operari: perscriptio interlock, impedita nexus vel culpa motoris.
• Asynchronous phases: Adjust cross-linkage rods.
• Contact overheating: Tersus et retighten; argentum patella reprehendo.

Project Reference

Cas-space erucae Duc Project

Project ReferenceProject Reference

Cas-space Rocket Launch ProjectCas-space Rocket Launch Project

Test Report

Test ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest Report

FAQ

Q1: Potestne GW4 Disconnect Switch aperiri vel claudi sub onere?

A: No. GW4 Disconnect Switch solum aptae ad solitariam et mutandi sub intentione solum, nullo onere. conditiones. Facultatem arcus exstinguendi non habet et ab operatione sub onere stricte prohibetur. It utendum est cum ambitu ruptor.

Q2: Quid est munus interlock mechanicae fundationis switch?

A: Mechanica interlock securam operantem seriem urget: principalis switch aperta → fundatio switch clausa; grounding switch open → main switch closed, preventing misoperation and mansing the safety of tuendae personas.

Q3: Potestne hoc productum adhiberi in alta altitudine vel in frigidis regionibus?

A: Vexillum genus ad ambitus cum altitudine ≤2000m ac temperie -40℃ ad +40℃ idoneum est; quae maxime necessariae substructiones velit occurrere; pro speciali summus altitudinis vel graviter inquinatus locis; velit confirmati et solutiones anti-corrosionis nativus esse potest.